SpectraMax® Microplate Reader Suite of Products Knowledge Base. SAN JOSE, Calif. Fluorescence Microplate Reader Comparison Chart. Plate stacker and robot integartion. (b) Fluorescence responses of probe HADP and control compounds 2–4 (each 5 µM) towards human heparanase (HPA) (1 µg) in 40 mM NaOAc buffer (pH 5. 2. View the Molecular Devices website. Extended linear dynamic range. FilterMax F3 and F5 Multi-Mode Microplate Readers are filter-based microplate readers offering fluorescence polarization, time-resolved fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements. SpectraTest ABS2 Absorbance Validation Plate SpectraMax iD3, iD5, i3x, i3, M2, M2e, M3, M4, M5, M5e,. Turn on Plate Reader and wait for it to complete its start-up routine. 1 up to 3600 sec. The SpectraMax® M2 and M2e Systems from Molecular Devices are multi- detection microplate readers with dual- monochromators, dual-mode cuvette ports, and top- and bottom-reading capability (top-reading only on the M2). The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. you might consider 300 W (at 120 Volts) per Spectramax reader, plus another 300 W for the Computer. Versa Max. 1-1. #6590-0108) Fluorescence detection using the SpectraMax iD5 reader’s monochromators for wavelength selection was compared to that using a filter pair specific for the Alexa594 tracer. Use a Phillips screwdriver to remove the screws, and then remove the plate from the instrument. , prior to compound addition) from the cells. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. With various on-board features and capabilities, the ThermoMax is ideal for use in modern laboratories. For more sample throughput, both readers can be easily. View SoftMax Pro GxP. Luminescence detection typically offers greater sensitivity than absorbance or fluorescence detection. This five-mode microplate reader with automatic filter identification and western blot capability is the complete. \r ( Molecular Devices ) equipment, software, reagents, and consumables to use in the operation of such Molecular Devices equipment, software, reagents, and consumables. The temperature in the plate chamber is ambient and isothermal. NORTH AMERICA. Page 16 FilterMax F3 and FilterMax F5 Multi-Mode Microplate Readers User Guide To exchange an excitation or emission filter in a slide: 1. If the computer is connected to the Internet: Select Search Automatically for. Download PDF. The instrument supports the following read modes:. Superior optical system includes a xenon flash lamp and features. By using PathCheck, SpectraMax readers can automatically normalize sample absorbance values to a 1-cm pathlength and calculate the concentrations. Instrument settings can be saved as a protocol file. These systems are hybrids that allow you to choose between. Monthly Plate Verification Check (Absorbance Validation Plate) Note: Monthly Plate Verification Check is maintained by Quality Control. and California)Our specialized plate readers for absorbance, fluorescence, and luminescence detection provide optimal sensitivity. 2 Software Release Notes. adipocytes: insulin dose-response. 0%, raw data units = counts/sec. Select Update Driver. * Filters (diameter) or optics shown as center wavelength/bandwidth (nm) & dichroic mirrors shown as cutoff wavelength (nm); Contact Molecular Devices for information on ordering filters & dichroic mirrors suitable with the microplate readers listed above. AlphaScreen assays cannot be done on the SpectraMax M series, Gemini, and SpectraMax iDx (iD3/iD5) readers. Testing can be done in the user’s lab on their own schedule. 1. Molecular Devices' microplate readers. or washer including mechanical, electrical, and optical components to verify operating functions are in accordance to the Molecular Devices product operational specifications. 00. #4TI-0214) UltraVision Plate 96 (Brooks Life. The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm - 850 nm). Table 2 summarizes the results for the uniformity test. The opaque walls prevent stray light from being detected from neighbouring wells for best accuracy. Get the most out of SoftMax Pro. As new assays are developed or your needs change, simply add a detection cartridge like ScanLater™ Western Blot System or the SpectraMax® MiniMax™ Imaging Cytometer option as opposed to buying a brand new system. Figure 1. 3 foot) See. The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Multimode microplate readers deliver both performance and economy. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. Cells were thawed and propagated according to the recommended method specified by the supplier. Since then, the microplate measurements of DNA, RNA, and proteins that this enabled have become very popular. Specifications subject to change without notice. The CellTiter-Glo assay from Promega uses luciferase. SpectraMax i3/i3x and Paradigm readers can be equipped with the HTRF detection cartridge. Important things to consider when purchasing a multimode microplate reader. and fluorescence microplate readers—. The wavelength required to excite the sample can be selected using either a filter of a specific wavelength or a monochromator tuned to the required. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. book Page 1 Wednesday, October 12, 2011 4:56 PMThe SpectraMax® i3x Multi-Mode Detection Platform measures spectral-based absorbance, fluorescence, and luminescence with the added functionality of modular upgrades for western blot, imaging, and fast kinetics with injectors. Figure 1. Details. HepG2 cells were plated into a 96-well clear-bottom, white-walled plate at 10,000 cells/well and incubated at 37°C. For a higher . The plate was then re-read on the plate reader (Read B). For biochemical assays, the washer removes unbound material and unreacted reagents. SpectraMax iD3 Multi-Mode Microplate Reader (Molecular Devices cat. Absorbance, fluorescence, and luminescence detection with upgradeable high-performance capabilities. View SoftMax Pro GxP. Luminescence reading is a secondary mode of the Gemini instruments. SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. 0077 OD 0. Set up template in SoftMax Pro and read plate on the SpectraMax M5 microplate reader: Note: IMAP FP protocols for use with FAM- and TAMRA-labeled substrates are available in SoftMax Pro 5 in the Binding Assays protocol folder. ABS Plus can run both cuvette-based and microplate reader applications on the same instrument. 0112-0127C 3 Contents SafetyInformation 5 Warnings,Cautions,Notes,andTips 5 Chapter1:Introduction 9 ComputerIntegration 11 InstrumentCovers 11 FluidicsModule 12Plate reader instructions Computer. 2. Vmax® plate reader specifications. The plate. The VersaMax Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Microplate Stacker and Washer. Step 3: Click “Settings” and a screen will appear (Figure 1). Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. 1-10 sec. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. 118. Purchase a new SpectraMax Multi-Mode Microplate Reader and. 24 deep well. The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed. SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. , target CV per well = 1. Powered by a new, optional high-speed EMCCD camera and the new Peak Pro 2 software module, the new FLIPR® Penta High-Throughput Cellular Screening System allows you to measure and analyze peaks of human-derived induced pluripotent stem cells (hiPSCs), differentiated into cardiomyocytes and neurons, up to 100 times per. We therefore gathered salient. Molecular Devices SpectraMax M5 Multi-Mode Microplate Reader. SpectraMax 340PC (Serial number starting with L) SpectraMax Plus (Serial number starting with P) Tmax Also refer to the Obsolete Microplate Reader Models. UV/Vis spectrophotometer & microplate reader with built-in cuvette port. SoftMax Pro Software. This page contains the. Absorbance Plate Reader Comparison Chart. Unplug the power cable from the back of the instrument. Step 2: Add sample to well – antigen within the sample binds to the capture antibody. Supplier: Molecular Devices. The plate reader. Uncontrolled Copy for Training and Reference Purposes Only . The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution designed to expand the boundaries of research capabilities. 0) at 37 °C, fluorescence intensity was recorded on a Spectramax M5 Multimode plate reader (Molecular Devices, USA) at each timepoint. 313 reference gain check fail. One plate carrier adapter is provided with the instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. Ratios for each sample were calculated as Read B/Read A. ABS2 Validation Plate Protocol Installation InstructionsEndpoint, dual read, kinetic, fast kinetic. 2. The SpectraMax 190 reader can be integrated with Molecular . 0. The reader measures both flat and round 96-well microplates and. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). Single- and multimode microplate readers are useful for very broad range of applications including ELISA, kinetics and high throughput screening assays. To maximize sensitivity of the assay, it is necessary to use optimal excitation and emission wavelengths. The resulting OD 426 values are visually represented above as a color map generated in the plate section of SoftMax. For more sample throughput, the system can be easily integrated into a full roboticThe SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). We would like to show you a description here but the site won’t allow us. Cell line development teams will realize savings on time and resources,SpectraMax i3x. Sunnyvale, CA - May 17, 2011 - Today, Molecular Devices, a leading provider of instruments, software, and consumables for drug discovery and life sciences research, announced that NanoRacks, LLC has chosen the SpectraMax® M5e Multi-Mode Microplate Reader for use in NASA's International Space Station; the M5e Reader will be the first. Multimode Microplate Readers. IMAP assays are based on binding of. Supersedes 1. Select the Driver tab. Combined with the analysis capabilities of SoftMax® Pro Software, we provide quantitation in an easy-to-read, user-customizableThe SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. The Beacon Melamine Plate Kit is a competitive enzyme-linked immunosorbent assay (ELISA) for the quantitative analysis of melamine in contaminated samples. S. Our specialized plate readers for absorbance, fluorescence, and luminescence detection provide optimal sensitivity. To update the driver. AXON Patch-Clamp. Increased throughput. With optimized reagents and the industry-leading data acquisition and analysis tool, SoftMax Pro® 7 Software, the SpectraMax® iD3. Complete plate reader solution for all your research needs For over 40 years, we have partnered with scientists to expand the boundaries of their research. 9000-0756. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax ® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Our multi-mode plate readers include absorbance, fluorescence, and luminescence with configurable options for fluorescence polarization (FP), time-resolved fluorescence (TRF), HTRF®, and AlphaScreen®. An end-to-end solution for high-content imaging and analysis. This technical note demonstrates validation of the SpectraMax® i3x Multi-Mode Microplate Reader for NanoBRET™ assays. Important things to consider when purchasing a multimode microplate reader. . The Analyst®, FlexStation® and SpectraMax® M5/M5 e from Molecular Devices have received the LanthaScreen® Certified designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance. Additional high-quality filters to. The microplate (containing standards) was incubated at 37ºC in the preheated SpectraMax ABS Plus reader for 10 minutes. Molecular Devices announced today the launch of the new SpectraMax ® iD5 Multi-Mode Microplate Reader, a feature-rich platform that expands the boundaries of scientific research. Molecular Devices launches custom organoid line expansion service using unique bioprocess technology for high-throughput applications. Our extensive SpectraMax® line of user-friendly microplate readers – the industry’s most cited brand – provide great. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Supersedes 1. , attenuation mode = out. EUROPE. These systems are hybrids that allow you to choose between. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. 997 (n = 3). The SpectraMax® M3 Multi-Mode Microplate Reader features dual monochromatic optics to allow the widest range of applications to be utilized for bioresearch procedures, without the need to change filters. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. Our systems for high-content imaging (HCI) and high-content analysis (HCA) provide flexible scalability making it easy to evolve your system alongside your research. Molecular Devices의 Microplate Reader 및 washer와 원활하게 호환되는 강력한 벤치탑 Microplate stacker입니다. (a) Chemical structures of 1 (HADP) and its analogues 2–4. SpectraMax readers support page; Analyst and FlexStation reader support page; Plate handlers and washers support page; We are continuously adding material to the knowledge base. Data acquisition and analysis. Absorbance Plate Reader Comparison Chart. #0200-6182). was added and absorbance was measured at 450 nm and 650 nm using a plate reader (Molecular Devices, SpectraMax ABS Plus, SoftMax Pro 7. Published Dec 16, 2020 | Updated Dec 16, 2020. 1). Hold down the green power button on the front of the instrument for 5 seconds or until the instrument power down. The system provides automation for up to 50 microplates for easy walkaway automation. Every step is optimized to simplify analysis and reporting to support our microplate readers. Gregory et al. *Purchase is subject to Molecular Devices standard terms and conditions of sale. Contact our support team with your questions regarding Molecular Devices products and applications. Fluorescence Filter with holder 565nm BW 30nm (Molecular Devices cat. (a) Chemical structures of 1 (HADP) and its analogues 2–4. SpectraMax® Paradigm Plate Reader Oksana Sirenko, Cathy Olsen, Vanessa Ott and Evan F Cromwell Molecular Devices, LLC, 1311 Orleans Drive, Sunnyvale, CA 94089 There has been a trend in the past decade from biochemical assays toward cell based assays. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. Molecular Devices SpectraMax 384 Plus Microplate Reader. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The ability to accurately quantitate cell number in multi-well microplates enables a multitude of biological applications that study cell health or proliferation. 0 OD for earlier models. Other features and benefits include: Eliminate changing out filters. However, when a specific probe is not available, or it causes off-target effects on the. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. This can increase throughput and efficiency, thus saving time and space in the lab. Title: SpectraMax i Series Multi-Mode Microplate Readers | Molecular Devices Author: Molecular Devices Subject: SpectraMax i Series offer the ideal solution for any application whether you are looking for an intuitive, easy-to-use reader, multi-user lab, or an upgradeable system that can adapt to support your lab s new projects. 190. the washer with a final aspirate height of 4. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. ¨Automated microplate readers reduce manual manipulation and ensure consistent operation. SoftMax® Pro Microplate Data Acquisition and Analysis Software Version 6 User Guide 5014177 C October 2011 FrameMaker_Export. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. 2. FlexIII. Contains a revised proprietary masking dye with higher light extinction in the extracellular solution to significantly reduce background and increase signal window. What plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for bottom reads. Contains one microplate adapter, five 24-well low volume slides, five 64-well low volume bottom slides, and five of each cover slide (2 µL and 4 µL) 0200-6267. and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. 1700 Online: Sales Offices USA/Canada 800. In . 0 OD for our latest microplate readers, SpectraMax® iD3, iD5, ABS, and ABS Plus readers, and up to 2. Molecular Devices' microplate readers. Molecular Devices' microplate readers. If the computer is connected to the Internet: Select Search Automatically for updated driver software. #S1205. Measure more accurately. High-precision 9 channel system; filter-less with up to 6 wavelengths. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. Luciferase reporter assays are widely used because of their sensitive detection capacity and broad dynamic range. The primary mode is fluorescence. M2. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The Back Panel Figure 1. The sample is typically placed in a cuvette through which light is sent horizontally. Incubate at RT. The adapter is required for optimum performance with standard 96-well and 384-. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. 1. User selects appropriate wells for samples and control using plate configuration tool. Published Dec 16, 2020 | Updated Dec 16, 2020. Detection of KASP genotyping reactions For the second test, the validation kit contained 36 known samples, including 33 DNA samples and 3 no-template controls (NTC). Molecular Devices launches custom organoid line expansion service using unique bioprocess technology for high-throughput applications. Use preconfigured wash, soak, and aspiration protocols or create your own multi-step protocol using the simple touchscreen interface. These robust readers have been placed in labs from. 10,700. begin reading microplates with seven mouse clicks. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. HTRF-compatible SpectraMax Multi-Mode Readers. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Increase productivity with patented microplate reader technologies. Evaluation of BioTek's Synergy H4 Plate Reader for Fluorescent Detection. Tutorial on how to quickly and easily view your results on the SpectraMax iD3 Multi-Mode Microplate Reader. The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. A. SpectraMax Readers have the most complete level of product validation and compliance. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices. Figure 1. Fluorescence Microplate Reader Comparison Chart. FLIPR. Also refer to the Multimode Reader Comparison Chart Features. The Synergy H4 is a convenient benchtop microplate reader that offers robust. Keywords: spectramax ABS microplate readers, spectramax ABS plus microplate readers, spectramax ABS readers, ABS plus microplate readers, ABS. 100 μL of each endotoxin standard was added to triplicate wells of an LAL Reagent Grade Multi-well Plate. The SpectraMax® M2 and M2e Systems from Molecular Devices are multi- detection microplate readers with dual- monochromators, dual-mode cuvette ports, and top- and. Our SpectraMax microplate readers and SoftMax Pro software are the industry's most cited and have empowered life science researchers to advance protein and cell biology―breaking the. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. M5. Page 17 Chapter 2: Setting Up the Instrument 4. Data analysis. W×D×H. This assay kit is optimized for SpectraMax microplate readers from Molecular Devices, with a pre. With SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. In addition, the iD5 reader measures TRF and FP and. Microplate Readers. Plate readers, also known as microplate readers or microplate photometers, are instruments which are used to detect biological, chemical or physical events of samples in microtiter plates. Molecular Devices, LLC Optical System: Inquire; Measuring Time: White light - 96-well/ 384 well microplate: <2 min Fluorescence - 96-well/ 384 well microplate: <8 min. One plate carrier adapter is provided with the instrument. The trademarks mentioned herein are the property of Molecular Devices, LLC or their respective owners. 340 PC384. Installation Qualification (IQ)the iD5 reader’s filter system. The SpectraTest® ABS1 Absorbance Validation Plate tests optical performance using NIST-traceable standards. This offer includes SpectraMax i3x, SpectraMax. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. Optimize wavelengths-protocols from Molecular Devices are on computer desktop. Lab automation for high-throughput plate-based assays. 2. Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. We would like to show you a description here but the site won’t allow us. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide 0112-0102 Rev. Page 28 Chapter 5: Read Modes and Read Types 1. ELISA Plate Readers / Microplate Readers. FLIPR Tetra systems are fluorescence- and luminescence-based microplate readers with an integrated 1536-, 384- or 96-pipettor. Three low volume 24-well bottom slides. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. 0 × 107) RLU 0. Microplate Reader Shelf. By using PathCheck, SpectraMax readers can automatically normalize sample absorbance values to a 1-cm pathlength and calculate the concentrations. 2 Software Release Notes. Materials • Quant-iT PicoGreen dsDNA Assay Kit, including lambda DNA standard (Life Technologies cat. Chapter 1: Introduction The SpectraMax® iD3 Multi-Mode Microplate Reader from Molecular Devices is a monochromator-based, multi-mode plate reader. After centrifugation, the plate was immediately read on the M5e and i3x readers using the instrument settings listed in Table 1. Microplate readers from Molecular Devices are designed to provide consistent performance for many years. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. With the novel filter system, assays such as hydrogen peroxide detection assays and IRantibody-binding assays can be run confidently with Molecular Devices set ofRead plate standard and mix. Turn on Plate Reader and wait for it to complete its start-up routine. Tests every subsystem of the reader or . 1. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Narrow bandwidths deliver increased accuracy and enhanced peak resolution. What plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for. Preventive Maintenance (PM) Each plate reader or washer is calibrated, inspected, and lubricated—any potential issuesSpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. 00. 5: Schematic of the back panel of a reader. Ultraviolet (UV) measurements in microplates became possible when Molecular Devices introduced the first UV-capable microplate reader. Read height should be optimized forIMAP phosphodiesterase assays on SpectraMax Multi-Mode Microplate Readers. Or, with the reader specifications noted from the Instrument. Molecular Devices' microplate readers. Products : SpectraMax i3x reader, SpectraMax iD5 reader, SpectraMax iD3 reader, General, FilterMax F5 reader, SpectraMax ABS reader, SpectraMax L reader, SpectraMax M5/M5e reader. July 17, 2023. FAST AND ACCURATE METERTECH Microplate Reader $3,650. 40266 Email: drugdiscoverytech@lifetech. the iD5 reader’s filter system. 5 hours. Microplate Reader, Multimode Molecular Devices SpectraMax M2e Multi-Mode Microplate Reader w/ SoftMax Pro. An absorbance plate reader offers higher throughput and can measure the absorbance of samples in microplates (typically 96-well or even 384-well) by sending light through each well. Assay flexibility. This can increase throughput and efficiency, thus saving time and space in the lab. Plate Formats: 6 to 384-well microplates. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. For more sample throughput, the system can be easily integrated into a full robotic The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter. SpectraMax Microplate Readers. Cellular Imaging Systems: Molecular Devices offers various imaging solutions for your research needs. Image courtesy of Molecular Devices. Supplier: Molecular Devices The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes. Made from polypropylene with conical well profiles to maximize recovery and allow working with sample volumes as low as 5 µl. Page 1 SpectraMax M3, M4, M5, and M5 ® Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010. the use of a reader calibrated with primary NIST and NMI standards. Urban myths of microplate readers. Fibroblasts vs. Turn on Plate Reader and wait for it to complete its start-up routine. Microplates for Molecular Devices Microplate Readers – Photometric Accuracy Fluorescence Intensity Luminescence Intensity (0. for SoftMax Pro Software. • Fluorescence Polarization (FP-FLUO) Detection Cartridge (Molecular Devices cat. Summary of Contents for Molecular Devices SpectraMax M2. e. Published Dec 16, 2020 | Updated Dec 16, 2020. Open the top cover of the instrument. ®Plate chamber design of the SpectraMax category 1 microplate readers. Imaging System Giles Scientific Biomic V3 Automatic Plate. (“Molecular Devices”) equipment, software, reagents, and consumables to use in the operation of such Molecular Devices equipment, software, reagents, and consumables. Do you want to learn how to use the FilterMax F3 and F5 Multi-Mode Microplate Readers for your research? Download the user guide and find out how to install, operate, and troubleshoot the instruments. Step 1: Open the SoftMax Pro IMAP FP protocol. #i3x) SpectraMax L Microplate Reader (Molecular Devices cat. 9. ; Page 2 Molecular Devices equipment, software, reagents, and consumables. HTRF-compatible SpectraMax Multi-Mode Readers. The touchscreen interface provides integrated instrument control, data display, and the ability to export results for statistical data analysis. ® Plate chamber design of the SpectraMax category 1 microplate readers. The SpectraMax® M3 Multi-Mode Microplate Reader features dual monochromatic optics to allow the widest range of applications to be utilized for bioresearch procedures, without the need to change filters. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. Restart the system. Recertification service. 3T3 L1 adipocytes were plated at 50,000 cells/well in 100 µL of DMEM/FBS in a 96-well plate and incubated at 37°C for five hours,Lower variance: Normalize your plate reader assay data to the number of cells in each well. In the M2, M5 and Plus.