The system comes with a single plate loading adapter and a choice of magazines for 20, 40 or 50 SBS-standard 96- and 384-well. Flip open the carriage door and using a flash light to check where the plate is stuck and whether it has been damaged. Single-mode Microplate Reader. To interrupt the kinetic measurement, the. Use preconfigured wash, soak, and aspiration protocols or create your own multi-step protocol using the simple touchscreen interface. 58% for the detection module and 2. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide — 0112-0102 Rev. Multimode microplate readers offer flexibility, and ease of use. Luminescence detection typically offers greater sensitivity than absorbance or fluorescence detection. The guidelines for cuvette use in SpectraMax instruments are the same as those that apply to any high-quality spectrophotometer. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. SpectraMax Mini Multi-Mode Microplate Reader (Molecular Devices P/N SMAX MINI AF), with fluorescence filter cube FL-535. Molecular Devices 推出了FlexStation® 3 多功能读板机系统。FlexStation 3 把 SpectraMax M5e 和 8 道 / 16 道的移液 系统整合在一起成为体积小巧功能强大的 读板机系统。该整合系统不但为用户提供 了多功能检测平台,还增加了液体处理的 通量和提升了检测生化和细胞动. Chapter 1: Introduction The SpectraMax iD3 Multi-Mode Microplate Reader from Molecular Devices is a monochromator-based, multi-mode plate reader. 50/50. Eliminate time-dependent substrate addition steps. D. Learn moreMolecular Devices has demonstrated the value of a variety of ELISAs for a wide range of research approaches,. The plate. Page 1 ™ VERSAmax Tunable Microplate Reader Operator’s Manual for Instruments with Serial Numbers Beginning with BN Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0084 Rev. to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, and. FilterMax F3 and F5 Multi-Mode Microplate Readers are filter-based microplate readers offering fluorescence polarization, time-resolved fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements. ABS2, FL1, and LM1 Validation Plates sent to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, an then returned with a new certificate of calibration. 9. Here, we demonstrate that with Molecular Devices SpectraMax® microplate readers and the Quant-iT PicoGreen assay, users can reliably measure concentrations as low as 50 pg/mL of double-stranded DNA. An end-to-end solution for high-content imaging and analysis. Important things to consider when purchasing a multimode microplate reader. Molecular Devices' microplate readers. The opaque walls prevent stray light from being detected from neighbouring wells for best accuracy. The Versamax Microplate Reader is built around a grating monochromator. View SoftMax Pro GxP. ~ Bio-Tek ELx808 Microplate Reader $2,795. It consists of a SpectraMax® Microplate Reader, Peak Robotics S-LAB Plate Handler with the S-LAB software, and the AquaMax® 4000 Microplate Washer. 0 software Download page. The plate reader optics are tunable for absorbance,. For biochemical assays, the washer removes unbound material and unreacted reagents. 313 reference gain check fail. PURPOSE. After reading the ELISA plate on both readers, each standard curve was nearly identical. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. Endpoint, kinetic, spectrum. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader. 세포신호전달은 세포가 환경에 반응하고 다른 세포와 소통할 수 있게 합니다…. Published Dec 16, 2020 | Updated Dec 16, 2020. Please click on the links below to view the Microplate Reader Comparison Tables. 3. Gregory et al. for SoftMax Pro Software. SpectraMax ABS and ABS Plus Microplate Readers are a compact and tunable absorbance microplate readers. Flexibility to read a variety of plate formats. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. washer including mechanical, electrical, and optical components to verify operating functions are in accordance to the Molecular Devices product operational specifications. Select Update Driver. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. 304 signal level saturation. For more sample throughput, the system can be easily integrated into a full robotic The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter. 1. 2 GxP Software is the latest, most secure software to achieve full FDA 21 CFR Part 11 and EudraLex Annex 11. Our SpectraMax microplate readers and SoftMax Pro software are the industry's most cited and have empowered life science researchers to advance protein and cell biology―breaking the. The SpectraMax® M2 and M2e Systems from Molecular Devices are multi- detection microplate readers with dual- monochromators, dual-mode cuvette ports, and top- and bottom-reading capability (top-reading only on the M2). 0 × 107) RLU 0. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Instrument settings can be saved as a protocol file. Contact Us Request Quote Microplate Reader Comparison Charts Published Dec 16, 2020 | Updated Dec 16, 2020 Products : General, FilterMax F5 reader Please. The primary mode is fluorescence. Part Number Description 1-2100-0548 USB computer connection cable, 3 meter (9. Firmly grasp the snap connector beside the snap, then push the snap down. Learn about the SpectraMax i3x Multi-Mode Plate Reader capabilities and options in this short video. FlexStation 3Multi-Mode Microplate Reader (Molecular Devices cat. Open the Protocol Library, locate the ‘Protein Quant’ folder, and open the pre-configured protocol ‘NanoOrange’. , Nov. “Sensitivity is pretty much clutch for luminescence,” says Daly. The StakMax system integrated with Molecular Devices microplate readers and AquaMax washers provides the walk-away automation for up to 50 microplates. 3 foot) See. ** Some compatible filter sets are available for purchase from Life. Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. With optimized reagents, option to operate the. Get the most out of SoftMax Pro. Microplate Reader, Multimode. The whole plate can be detect in a single run with ease and flexible. Select the Driver tab. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. (“Molecular Devices”) equipment, software, reagents, and consumables to use in the operation of such Molecular Devices equipment, software, reagents, and consumables. The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. M5. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide 0112-0102 Rev. These plate readers in the list below, are no longer included with the new SoftMax Pro 6 reader menu. S. Plate layout configuration. PBS was removed, and cell pellets were. Molecular Devices announced today the launch of the new SpectraMax ® iD5 Multi-Mode Microplate Reader, a feature-rich platform that expands the boundaries of scientific research. Microplate readers detect and process biological and chemical data using absorbance (ELISAs, enzyme activity, and nucleic acid and protein quantification), luminescence, and fluorescence detection modes, including intensity, TRF, and polarization. Molecular Devices training courses and tutorials. to that of dedicated single-mode readers. Page 2 SpectraMax ® SpectraMax ® Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089. #6590-0118) Filter 665/10 (Molecular Devices cat. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M5e Microplate Reader transforms each well in a microplate to a fixed. Plus 384. V. Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0140 Rev. Chirag Patel, a graduate student at Johns Hopkins, reviewed Molecular Devices' SpectraMax M5 Multi-Mode Microplate Reader and. Visible absorbance -. FlexStation® 3 Multi-Mode Microplate Reader. Molecular Devices의 Microplate Reader 및 washer와 원활하게 호환되는 강력한 벤치탑 Microplate stacker입니다. S. A microplate reader with fluorescence intensity (FI) detection uses a light source, usually a Xenon flash lamp or LED, to excite a fluorophore (fluorescent molecule) at a particular wavelength. , Sunnyvale, CA 94089, USA, Jin_Liao@moldev. 0%, raw data units = counts/sec. STAKMAX. 5. By using PathCheck, SpectraMax readers can automatically normalize sample absorbance values to a 1-cm pathlength and calculate the concentrations. The following components are located on the back panel of the SpectraMax and VersaMax readers: • Power switch:[The Multi-Mode Validation Plate offers additional testing of TRF, HTRF, and fluorescence polarization read modes on FilterMax™ F3/F5 and SpectraMax® i3x, iD5, and Paradigm® microplate readers. For top-reading microplate readers (SpectraMax M2, M5, FlexStation II, and FlexStation 3) is it fine to leave the plate lid on? Will the excitation light get reflected off the lid in an unpredictable way?Sunnyvale, California -- October 5, 2017. Single- and multimode microplate readers are useful for very broad range of applications including ELISA, kinetics and high throughput screening assays. or washer including mechanical, electrical, and optical components to verify operating functions are in accordance to the Molecular Devices product operational specifications. The calculated LOQ values were 0. 2. To update the driver. One plate carrier adapter is provided with the instrument. is user upgradeable—from 2 to 3 modes, providing researchers with a versatile instrument that does not compromise on . With SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. Page 1 of 8 . This assay kit is optimized for SpectraMax microplate readers from Molecular Devices, with a pre. Read one sample or up to 384 in a. Monthly Plate Verification Check (Absorbance Validation Plate) Note: Monthly Plate Verification Check is maintained by Quality Control. The SpectraMax® Mini multi-mode microplate reader offers a budget friendly solution that gives you exactly what you need when you need it. Molecular Devices SpectraMax M5 Multi-Mode Microplate Reader. Combined with the analysis capabilities of SoftMax® Pro Software, we provide quantitation in an easy-to-read, user-customizableThe SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. The trademarks mentioned herein are the property of Molecular Devices, LLC or their respective owners. The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. Cell line development teams will realize savings on time and resources,SpectraMax i3x. 4: Test tube cover. Fortunately, Molecular Devices’ SpectraMax i3x and iD5 readers offer the best of both worlds. These lab workhorses are used in drug discovery. 96-deep-round-well-plate, 384-deep-square-well-plate, 24-deep-well-plates. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. . Eight filter options provide simplified assay setup. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). The VICTOR® Nivo™ system packs all popular detection modes into the industry’s smallest multimode reader footprint. 9. FAST AND ACCURATE METERTECH Microplate Reader $3,650. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. generation SpectraTest ABS2 Absorbance Validation Plate. These models can no longer be repaired. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. Image courtesy of Molecular Devices. 9. EMax. #0200-6182). SpectraMax Paradigm Microplate Reader is a versatile and customizable device that can perform a wide range of detection modes, such as absorbance, fluorescence, luminescence, time-resolved fluorescence, and AlphaScreen. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and. Microplates for applications that require high sample recovery rates. The SpectraTest® ABS1 Absorbance Validation Plate**4 °C above ambient to 45 °C. the iD5 reader’s filter system. D SpectraMax® M2 SpectraMax® M2e Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0102 Rev. A. Use all black plate. Our microplate readers and software are the industry’s most cited and have empowered life science researchers to advance protein and cell biology. The touchscreen interface provides integrated instrument control, data display, and the ability to export results for statistical data analysis. Microplate Readers. 1. One plate carrier adapter is provided with the instrument. to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, and. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The assay is easy to set up and the range of potential analytes is vast, but the assay procedure is time consuming and labor intensive. SoftMax® Pro 7. M2. Cet appareil ISM est confomre à la norme NMB-001 du Canada. Select Start>Control panel>Device Manager. Recombinant protein expression Nucleocapsid. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. SpectraMax® 190 Absorbance Plate Reader, Molecular Devices. HTRF-compatible SpectraMax Multi-Mode Readers. Contains one microplate adapter, five 24-well low volume slides, five 64-well low volume bottom slides, and five of each cover slide (2 µL and 4 µL) 0200-6267. 150 μL of MTT solvent was then added to each well to solubilize the formazan product, and the plate was placed on a shaker for 15 minutes. Microplate Reader Shelf. The ability to accurately quantitate cell number in multi-well microplates enables a multitude of biological applications that study cell health or proliferation. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Select the Driver tab. Laboratory automation workflows can help. +1 800-635-5577. #Flex3) Methods. 340 PC384. The reader measures both flat and round 96-well microplates and. 8 foot) 4400-0002 Power cord, 1 meter (3. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. Find our technical support information along with contact details. Contains a revised proprietary masking dye with higher light extinction in the extracellular solution to significantly reduce background and increase signal window. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. com Setup for Z’-LYTE® Assay on SpectraMax® M5/M5e. SpectraMax i3/i3x and Paradigm readers can be equipped with the HTRF detection cartridge. 0) OD (0. Complete plate reader solution for all your research needs For over 40 years, we have partnered with scientists to expand the boundaries of their research. Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. Validating the absorbance optical performance of your microplate reader is as simple as reading a plate. Restart the system. Three low volume 24-well bottom slides. Molecular Devices makes. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Plate stacker and robot integration The SpectraMax ABS readers can be integrated with Molecular Devices StakMax® Microplate Stacker within minutes and begingene expression with a user-friendly reader. begin reading microplates with seven mouse clicks. FlexIII. Turn the reader on and secure the USB cable. plate readers. Next generation SpectraMax® absorbance microplate readers. Table 1: FLIPR hardware settings for a cell plate basal fluorescence signal test. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time. . The BCA assay plate was read at 562 nm, the original wavelength setting in the protocol, while for the BCA Rapid. SoftMax® Pro Microplate Data Acquisition and Analysis Software Version 6 User Guide 5014177 C October 2011 FrameMaker_Export. Molecular Devices i3x. 0 . Highly customizable low volume applications Molecular Devices unique SpectraDrop™ Micro-The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. A plate reader’s software may offer automated analysis using protocols configured for a particular assay. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Other features and benefits include: Eliminate changing out filters. With three modes of detection for UV/Vis absorbance, fluorescence and luminescence, the SpectraMax®. 10,700. Check pages 8-42 to 8-46 of the user manual. Citations on Google Scholar. Figure 1. 635. Dual monochromators increase performance and assay flexibility. SpectraMax Microplate Reader - Choose from our extensive SpectraMax® line of user-friendly microplate readers. Get any of the iD series microplate readers with up to 25% discount off the current list price in their basic configuration and receive a two-year warranty for commercial or a three-year warranty for Academic customers. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. 0112-0174C 3 Contents SafetyInformation 4 Warnings,Cautions,Notes,andTips 4 Chapter1:Introduction 7 InstrumentFeatures 8 ComputerIntegration 9 PMTTechnology 9Results shown are from the SpectraMax M5 microplate reader, but similar results are obtained with other Molecular Devices readers with fluorescence detection mode (data not shown). SpectraMax® Microplate Readers and SoftMax® Pro Software. SpectraMax® 190 Absorbance Plate Reader, Molecular Devices Supplier: Molecular Devices Enables data acquisition in endpoint, kinetic, and spectral scan modes at. The SpectraMax® QuickDrop™ UV-Vis Spectrophotometer quantifies very small amounts of DNA, RNA, oligos, and proteins. Use the 1. 5 µL of each sample was pipetted into a 96-well. IMAP® Technology from Molecular Devices enables rapid, homogeneous, and non-radioactive assay of kinases, phosphatases, and phosphodiesterases and is suited for both assay development and high-throughput screening. ®This document is provided to customers who have purchased Molecular Devices, Inc. 0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-Mode The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. ELISA Plate Readers / Microplate Readers. Molecular Devices SpectraMax M5 Multi-Mode Microplate Reader. For a higher . It may be named "Pothos". The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. The Spectratest® Abs1 plate, which is used for validationof Molecular Devices monochromator based readers, cannot be used to validate the Emax/Vmax readers. Molecular Devices SoftMax ® Pro software was used to analyze and present the data. Microplates for Molecular Devices Microplate Readers – Photometric Accuracy Fluorescence Intensity Luminescence Intensity (0. FLIPR. Molecular Devices is one of the leading provider of high-performance bioanalytical measurement solutions for life science research, pharmaceutical and biotherapeutic. 7°C (gradient heating design). When the user applies a set temperature of 37°C, the top is heated to 37. ABS Test results. SoftMax Pro Software. Reader Documentation Version No. Tutorial on how to quickly and easily view your results on the SpectraMax iD3 Multi-Mode Microplate Reader. Preventive Maintenance (PM) Each plate reader or washer is calibrated, inspected, and lubricated—any potential issuesSpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. It was then read from the bottom on a SpectraMax ® i3 Multi-Mode Microplate Reader using a preconfigured protocol in SoftMax Pro Software with the settings indicated in Table 1. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. 5 minutes (ValitaTiter) 15 minutes (ValitaTiter PLUS) Integrating ValitaTiter and Molecular Devices fluorescence polarization (FP) plate readers produces a seamless IgG titer assay setup and optimization. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. The Back Panel Figure 1. Evaluation of BioTek's Synergy H4 Plate Reader for Fluorescent Detection. 2. 2. #X7060. An IL-22 standard curve was prepared and a sandwich ELISA performed using the MultiWash+ plate washer in strip mode to wash the wells. We would like to show you a description here but the site won’t allow us. In an analogous manner, the same sample names were assigned to a CuvetteSet section. Description Figure 1. Important things to consider when purchasing a multimode microplate reader. The plate reader can measure multiple readouts, including UV and. Toggle navigation 0 Cart; Store. The Bauer Core Facility at Harvard University offers of variety of plate-reader choices to its users (mostly from Molecular Devices), and the SpectraMax® L is preferred for luminescence rather than the core’s multimode readers. 306 plate air cal. Support. User selects appropriate wells for samples and control using plate configuration tool. 1. 9. This document outlines references to 21 CFR Parts 58, 211 and 820 and EudraLex Annex 15 to assess the implementation of Molecular Devices microplate readers in regulated environments. 0077 OD 0. This page contains the. The purpose of this procedure is to set instructions in the proper use and handling of the Molecular Devices M5 Plate Reader. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). The variations include adjustable speed and volume, adjustable aspiration speed and time, adjustable soak times, and three modes of. #S1207. Purchase a new SpectraMax Multi-Mode Microplate Reader and. Made from polypropylene with conical well profiles to maximize recovery and allow working with sample volumes as low as 5 µl. ©2012 Molecular Devices, LLC | 8/12 | Printed in USA | PN: 0120-1527. Use preconfigured wash, soak, and aspiration protocols or create your own multi-step protocol using the simple touchscreen interface. Title: SpectraMax i Series Multi-Mode Microplate Readers | Molecular Devices Author: Molecular Devices Subject: SpectraMax i Series offer the ideal solution for any application whether you are looking for an intuitive, easy-to-use reader, multi-user lab, or an upgradeable system that can adapt to support your lab s new projects. 1 second up to 30 seconds. Users of Molecular Devices' SpectraMax® i3 Multi-mode reader can even add an optional. 8000. SpectraMax Readers have the most complete level of product validation and compliance. Devices PathCheck® Sensor—the only patented technology available that measures the depth (optical pathlength) ofWe would like to show you a description here but the site won’t allow us. To update the driver. coli stock with an OD 600 value of 0. (b) Fluorescence responses of probe HADP and control compounds. 6 % of reading 4. Complete plate reader solution for all your research needs For over 40 years, we have partnered with scientists to expand the boundaries of their research. Standalone instrument with touchscreen and built-in sample ports for small volumes and cuvettes. If the computer is connected to the Internet: Select Search Automatically for. 0. 5: Schematic of the back panel of a reader. Cell Cytotoxicity assay procedureMolecular Devices. LMax and LMax II RLUs are proportional to (counts/sec) x (integration time), so for these readers if the signal is constant, doubling the integration time doubles the RLU. What plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for. The drawing shows a standard microplate of 15 mm height covered with a lid. They are widely used in research, drug discovery, [1] bioassay validation, quality control and manufacturing processes in the pharmaceutical. Molecular Devices provides web-based tutorials (webinars) and training courses throughout the year. In addition, the iD5 reader measures TRF and FP and. Tristar 3 Multimode Microplate Reader. Step 3: Click “Settings” and a screen will appear (Figure 1). 1 sec. #4TI-0655) Microplates. We would like to show you a description here but the site won’t allow us. PURPOSE. SoftMax Pro GxP Software. the use of a reader calibrated with primary NIST and NMI standards. The ScanLater Western Blot Detection Cartridge is a user-installable option for the SpectraMax i3, i3x and Paradigm Multi-Mode Readers. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. Every step is optimized for data acquired from a Molecular Devices microplate reader or data imported from. 9000-0756. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. For 40 years, we have partnered with scientists to help them achieve landmark discoveries. The guide also covers the software features, the specifications, and the accessories of the systems. By measuring optical pathlength, it eliminates the last. Specialized filters allow for IR fluorescence detection ranging from 10-40 times more sensitive than conventional monochromator detection reader. Detection modalities include absorbance (UV-Vis Abs), fluorescence intensity (FI), luminescence (Lumi), and all have. Products : SoftMax Pro Software, SoftMax Pro GxP Software, CellReporterXpress software, General, Screenworks, pCLAMP/AxoScope, GenePix Pro, MetaXpress software Check software compatibility with Windows 10 and locate your software installer. The CellTiter-Glo assay from Promega uses luciferase. Spectrofluorometers or plate readers with fluorescence detection typically offer greater sensitivity and a wider dynamic range compared to absorbance detection. 00. 020 OD 2. • Fluorescence Polarization (FP-FLUO) Detection Cartridge (Molecular Devices cat. How to import latest protocol revisions into SoftMax Pro Protocol Library; Protocols for the ABS2 Validation Plate. This document is provided to customers who have purchased Molecular Devices, Inc. Wide photometric range Temperature-regulated Thermal control and vertical shake Microsoft Windows-based software Automatic mixing Five-second read per plate Photometric and kinetic analysis mode The Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices. SoftMax Pro Software. Your applications, your modes, your choice. Sunnyvale, CA - May 17, 2011 - Today, Molecular Devices, a leading provider of instruments, software, and consumables for drug discovery and life sciences research, announced that NanoRacks, LLC has chosen the SpectraMax® M5e Multi-Mode Microplate Reader for use in NASA's International Space Station; the M5e Reader will be the first. The optical system uses two scanning monochromators so you can determine optimal excitation and emission settings, resulting in. Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, CA 94089 USA Tel: 408. Endpoint. The plates were then read with the SpectraMax M3 plate reader (Molecular Devices, Sunnyvale, CA) to obtain absorbance readings at 570 nm. Materials • Quant-iT PicoGreen dsDNA Assay Kit, including lambda DNA standard (Life Technologies cat. The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed to be \~50 µg/mL for a 1-cm pathlength3,4. Our extensive SpectraMax® line of user-friendly microplate readers – the. Ensure data accuracy of your reader. Shaking. Lab automation for high-throughput plate-based assays. The Molecular Devices SpectraMAX absorbance microplate readers mimic a dual beam spectrophotometer with a patented multichannel optical design. 305 reference level saturation. Superior optical system includes a xenon flash lamp and features.